Kodak Trendsetter CTP - Coarse Focus Find Failed Repair
Introduction
This document details the repair of a Kodak Trendsetter CTP system experiencing a ‘Coarse Focus Find Failed’ error. DTP TECH leverages our expertise to minimize downtime and restore optimal performance for used CTP equipment.
Machine Information
- Machine Model: Kodak Trendsetter 800
- Machine Series: Trendsetter
- Laser Head Model: TH5
- Fault Code: Coarse Focus Find Failed
Fault Symptom
The machine failed during startup self-check and could not complete the focus scan.
Initial Diagnosis
Upon initial assessment, the diagnostic process involved verifying the startup sequence, evaluating the laser head functionality, and examining the CRB signal output. The ‘Coarse Focus Find Failed’ code indicated a problem with the system's ability to accurately determine the optimal focus position.
Inspection Process
- Verified the power supply and connection to the CTP system.
- Performed a thorough inspection of the laser head optical path for contamination and debris.
- Measured and recorded the Z focus position.
- Analyzed the CRB (Critical Bar) signal strength and waveform.
- Checked the mechanical movement of the laser head for smooth and precise operation.
Root Cause
Weak CRB signal, resulting from optical contamination and a slight deviation in the Z focus position, were identified as the root cause. The contamination affected the laser beam’s accuracy, while the Z focus position misalignment prevented the system from achieving optimal focus.
Repair Solution
- The optical path was meticulously cleaned using appropriate optical cleaning solutions and microfiber cloths.
- The CRB signal strength was verified and corrected through signal amplification.
- The Z focus position was precisely adjusted to eliminate the deviation.
- A full edge find and focus scan was executed to confirm the system’s ability to accurately determine the focus.
Final Test Result
Following the repair solution implementation, the CTP system successfully completed the startup self-check and the focus scan, demonstrating stable and accurate focus performance.
Technical Notes
- ‘Coarse Focus Find Failed’ errors are frequently associated with CRB signal issues or mechanical misalignment within the laser head. Regular maintenance and optical cleaning are crucial to prevent these issues.
- Accurate Z focus adjustment is critical for optimal image quality and plate consistency.